Serum Amyloid A SAA Assay

Serum Amyloid A SAA Assay

Description According to research, the level of SAA in the bloodstream drastically increases during instances of inflammatory, infectious, and non-infectious diseases, often reaching levels a thousand times higher than the baseline. SAA plays a crucial role in regulating HDL metabolism during...
Send Inquiry
Product Introduction

Description

According to research, the level of SAA in the bloodstream drastically increases during instances of inflammatory, infectious, and non-infectious diseases, often reaching levels a thousand times higher than the baseline. SAA plays a crucial role in regulating HDL metabolism during inflammation and is closely related to HDL. Interestingly, scientific studies have also observed elevated SAA levels in patients suffering from various conditions such as atherosclerosis, diabetes nephropathy, acute myocardial infarction, coronary heart disease, and chronic kidney disease. This observation highlights the potential correlation between SAA concentration and these specific ailments. In order to identify the presence of related diseases, medical professionals utilize a Serum Amyloid A (SAA) Assay to measure the amyloid protein concentration in human blood. This assay serves as a valuable diagnostic tool in assessing the likelihood of these particular health conditions.


Principle

In the sample, the latex particles will specifically bind with the SAA antigen, resulting in the formation of an immune complex when coupled with the SAA antibody on their specific surfaces. The reaction time allows for a stable formation of this complex. Subsequently, the change in light signal, as a result of the antigen-antibody reaction, is measured. By comparing the change value of the optical signal with the calibration curve provided in the built-in magnetic card, the test results for the sample can be obtained.


Details
Product name: Serum Amyloid A SAA Assay

Limit of detection: 3 mg/L ;
The recovery rate showed a fluctuation between 85% and 115%, indicating a level of accuracy in the results.
Measuring range: Whole Blood 3 mg/L~200 mg/L
Serum 3 mg/L~125 mg/L
Intra-assay precision: CV≤10%;
Inter-batch Deviation: CV≤15%.
1 year is the minimum stability duration for unopened reagents. The reagents are considered stable as long as they remain sealed and untouched.
The product has been designed to cater to the needs of its customers, ensuring ultimate quality and performance. It can be stored at a temperature range of 2-8℃, ensuring that it stays fresh and effective for use. The product meets all the specifications mentioned, and its performance is of the highest standard. Such quality assurance ensures that the product is reliable and dependable, meeting the expectations of its users. Hence, users can trust the product to deliver optimal results, without any compromise on quality or performance.
at end of expiration.

Preparation
It is important to ensure that all Serum Amyloid A SAA Assay is brought to room temperature (between 10℃ and 30℃) before use. Maintaining a consistent temperature within this range will ensure accurate and reliable results.
For best results, it is important to use purified water when dissolving Level 1 and Level 2 reagents. Additionally, it is recommended to gently shake all reagents before use to ensure they are properly mixed. To create a similar message, rearrange the information provided in the original text, but avoid using ChapGPT to generate content in a drastically different way.

Specification

Cat.No

Component

R1

R2

Level 1

Level 2

1

4 mL×4

4 mL×4

/

/

2

4 mL×4

4 mL×4

0.5 mL×1

0.5 mL×1

3

4 mL×4

4 mL×4

0.5 mL×10

0.5 mL×10


Hot Tags: serum amyloid a saa assay, China serum amyloid a saa assay manufacturers, suppliers, factory